computer keyboard, cup of coffee, pen and paper

Web Server & Hosting Technology

Our full-service hosting includes improvements, updates, and other graphic and content revisions or additions that are necessary to keep your website fresh, informative, and accurate for the duration of the hosting agreement. This includes the design and development of additional web pages (not to exceed 10 additional web pages per year/per site unless otherwise agreed upon by both parties).

Our hosting services include the “housing” for the website on a server that is permanently connected to the internet.

Data Center Space

  • SAS 70 Type II Certified
  • PCI Compliant
  • Square footage: 18,500 (Facility); 12,620 (Colocation & Managed)
  • 100% Dedicated Hosting.com resources
  • 12-inch Raised floor allows for more efficient airflow
  • Overhead cable management for easy expansion
  • Fire Detection: Fike Cheetah Photoelectric and VESDA
  • Fire Suppression: Fike FM-200 / Pre-action dry-pipe

Configurations & Support

  • APC AR3100 78.4” x 23.6” x 42.1” cabinets available at full and half rack increments
  • Cabinets are lockable, fire-rated with perforated front and rear doors for sufficient airflow
  • 100+ sq ft Cage space available
  • 2300 sq ft private space available
  • Roof rights are not available

Data Center Power

  • N+1 Redundant power and power feeds
  • Up to 150 watts/square foot
  • Automatic transfer switches designed for seamless cutovers
  • 3.7 mW of total building power capacity over 2 utility feeds
  • N+1 Redundant UPS Systems
  • 4.5 mW of generator capacity with 36+ hr of fuel capacity
  • Generators housed in dedicated, fenced, secure enclosures
  • Over 6000 gallons of onsite available fuel

Customer Power

  • 120V and 208V Circuits
  • Redundant power is delivered via diverse patch panels and PDUs
  • Power whips are provided for 30 amp 110/208v
  • Power installed in sealed steel conduit under the subfloor

Cooling

  • N+1 HVAC redundant cooling system
  • 20 Liebert System 3 30 ton computer room air conditioners
  • Cooling up to 175 watts/sq ft
  • Temperature maintained at 70°F (+/- 4°)
  • Humidity maintained at 40% (+/- 5%)

Bandwidth

  • Redundancy and automatic failover in place to ensure continual connectivity
  • 10 GB Redundant capacity delivered from two major POPs
  • 8 GB committed transit from four separate providers
  • Engineered to greater than 200% peak utilization
  • Fully meshed routing and switching architecture
  • Connectivity via multiple backbone providers
  • Network boasts multi-homed bandwidth
  • 2 Diverse points of entry and 2 diverse paths
  • Copper CAT 5E and Fiber access to each row of cabinets and cages
  • 100 Mbps or 1 GB network connectivity available to cabinets and cages

Security

  • Facility security includes keycard access and on-site Operations personnel
  • Video monitoring via both interior and exterior cameras
  • Video data retained for 30 days
  • 24x7x365 Customer access
  • Fully staffed 24x7x365 Operations Center & Remote Hands